14 Quadra-Fire • QV36DB • 2017-900 Rev. C • 5/05
Figure 6. Straight Up Vertical Venting
STRAIGHT UP
VERTICAL VENTING
V (FT.)
40' MAX. (12.4 M)
CAP
V
Flue Restrictor Instructions
1. Remove Exhaust Shield using a 1/4” nut driver by
removing the four screws securing it in place (see
Figure 7).
Figure 8. Flue Restrictor
BREAK
HERE
Figure 7
EXHAUST
SHIELD
FLUE
RESTRICTOR
2. Break the Flue Restrictor into two pieces. Do this
by bending the part back and forth until it breaks
(see Figure 8).
NOTE: On vertical venting configurations over 10 feet install
the flue restrictor (385-128). See flue restrictor installation
instructions.