DO NOT DISCARD THIS MANUAL
NOTICE
Important operating
and maintenance in-
structions included.
Leave this manual with
party responsible for
use and operation.
Read, understand and
follow these instructions
for safe installation and
operation.
DO NO
T
DIS
C
AR
D
WARNING
If the information in these instruc-

may result causing property damage,
personal injury, or death.
Do not store or use gasoline or other

vicinity of this or any other appliance.
 


Comply with all minimum clearances to



5100-I ACT WOOD INSERT
Advanced Combustion Technology (ACT)
438-0380E
R
Installation and service of this appliance should


professionals, or technicians supervised by an


WARNING


poisonous gases (i.e. carbon monoxide).
April 21, 2010

Glass and other surfaces are
hot during operation and cool
down.
WARNING
Hot glass will cause burns.
Do not touch glass until it is cooled

Keep children away
 
as appliance
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
ammable materials.
Keep clothing, furniture, draperies and other
combustibles away.
Model:
5100I-GD-B
5100I-NL-B
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Vista de pagina 0
1 2 3 4 5 6 ... 43 44

Indice de contenidos

Pagina 1 - 5100I-NL-B

DO NOT DISCARD THIS MANUALNOTICE• Important operating and maintenance in-structions included.• Leave this manual with party responsible for use

Pagina 2 - ATTENTION:

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EF. Hearth Extensionthe portion of

Pagina 3 - TABLE OF CONTENTS

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010NOTE: If your home is fairly airtight, it is recommend that you install the outside air that

Pagina 4 - Listing and Code Approvals

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380Eat the factory with the power cord o

Pagina 5 - Getting Started

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Figure 13.1C. Wiring Diagram&AN#ONTROL3PEED#ONTROL2HEOSTAT3NAP$ISC3NAP$ISC"

Pagina 6 - C. Negative Pressure

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380E D. Masonry Chimney      

Pagina 7 - E. Tools And Supplies Needed

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System Follow Manufacturer’s

Pagina 8 - FRONT VIEW

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EF. Prefabricated Metal ChimneyFigure 16.1E. Metal Heat Circulating Masonry

Pagina 9 - Hearth Extension

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Minimum Width of Cavity Opening 36 914 24 607 19

Pagina 10 - F. Hearth Extension

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EOvalizing round stainless steel liners to accommodate the 

Pagina 11 - Installation Considerations

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010L. Chimney Termination Requirements

Pagina 12 - Top of grille

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380Eand Welcome to the Quadra-Fire Family!        

Pagina 13 - Figure 13.2

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EArestor Cap Double Wall 

Pagina 14 - Chimney Requirements

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Figure 21.1Figure 21.2Figure 21.3Two leveling bolts, 3/8” x 4” are shipped inside the com-pone

Pagina 15 - Masonry Chimney (Cont’d)

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EFigure 22.1Figure 22.2Option One

Pagina 16 - Combustible Floor

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Figure 23.1Figure 23.2Figure 23.3Figure 23.4E. Zero Clearance Adjustable Trim SupportSize: 12

Pagina 17 - 250-2061

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EB. Wood Selection & Storageof th

Pagina 18 - K. Air Clearances

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 20102. Second Stage

Pagina 19 - Pitched Roof

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EOdors and vapors released during initial operation.• Curing of high temperature paint.• Open

Pagina 20 - Mobile Home Installation

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010snap disc which will automatically t

Pagina 21 - Appliance Set-up

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380ECORRECT POSITIONINCORRECT POSITIONS-ment is not cover

Pagina 22 - Attach liner with 2 tabs

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010 Odors and vapors are released during initial operation.• Curing of high temperature paint.•

Pagina 23 - (

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Section 1: Listing and Code Approvals   ...4 

Pagina 24 - Operating Instructions

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380E9Maintaining & Servicing Your ApplianceA. General MaintenanceInspection: Inspect the syst

Pagina 25 - D. Building A Fire

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 20104. Glass Cleaning• Frequency: As necessary• By:• Task: Clean glass with a

Pagina 26 - F. Opacity

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EB. Quick Reference Maintenance Guide22-

Pagina 27 - G. Air Controls

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010     

Pagina 28 - INCORRECT POSITIONS

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EE. Door Handle Assembly Replacement1. Install washer on door handle shaft. 

Pagina 29 - ISSUES SOLUTIONS

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010         

Pagina 30 - A. General Maintenance

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EH. Bafe Removal• Frequency: As needed• By:• Task:

Pagina 31

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 201010TroubleshootingWith proper installation, operation, and maintenance your appliance provide

Pagina 32

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380E11Reference MaterialsA. Exploded DrawingsFigure 38.17025-026 5-14-09

Pagina 33

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010B. Service Parts & AccessoriesWhen requesting service or replacement parts for your ap

Pagina 34 - 2 Screws

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380E1Listing and Code Approvals

Pagina 35 - Nbr Brick Size Qty

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380ETo order the entire assembly, order the top line part number only. To order an individual part

Pagina 36 - H. Bafe Removal

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010To order the entire assembly, order the top line part number only. To order an individual part

Pagina 37 - Troubleshooting

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EC. Warranty Policy

Pagina 38 - Reference Materials

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010

Pagina 39

 April 21, 2010438-0380ERHearth & Home Technologies1445 North HighwayColville, WA 99114Division of HNI INDUSTRIESCONTACT INFORMATION:Pleas

Pagina 40

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Improper installation, adjustment, alteration, service or maintenance can cause injury or prope

Pagina 41

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380EC. Negative PressureDraft is the pressure difference needed to vent appliances 

Pagina 42 - C. Warranty Policy

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010D. Flue Draft ConsiderationsLocation of the appliance and chimney will affect perfor-m

Pagina 43

5100-I ACT WOOD INSERTApril 21, 2010R 438-0380E3Dimensions and ClearancesA. Appliance DimensionsTOP VIEWSIDE VIEWFRONT VIEWAB39-1/8" (99

Pagina 44

 5100-I ACT WOOD INSERTR 438-0380EApril 21, 2010Hearth Extension ABCFEInsertSideWall Fascia or Trim Mantel DMaximum Mantel Depth: 12 inches (30